volume_backwards_scattering_coefficient_of_radiative_flux_in_air_due_to_aerosol_particles_at_standard_temperature_and_pressure

accepted
Created: May 5, 2023
Proposer: Markus Fiebig
Proposed Date: 2021-09-22
Created by bulk upload
Change Date: May 5, 2023, 1:46 p.m.
Term: volume_backwards_scattering_coefficient_of_radiative_flux_in_air_due_to_aerosol_particles_at_standard_temperature_and_pressure
Unit: m-1
Unit ref: UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with specific_ instead of volume_. Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths, unless a coordinate of radiation_wavelength is included to specify the wavelength. "Aerosol" means the system of suspended liquid or solid particles in air (except cloud droplets) and their carrier gas, the air itself. To specify the relative humidity at which the sample was measured, provide a scalar coordinate variable with the standard name of "relative_humidity". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "Standard_temperature_and_pressure" refer to a reference volume at 273.15 K temperature and 1013.25 hPa pressure.
Change Date: Dec. 19, 2023, 2:10 p.m.
Term: volume_backwards_scattering_coefficient_of_radiative_flux_in_air_due_to_aerosol_particles_at_standard_temperature_and_pressure
Unit: m-1
Unit ref: UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with specific_ instead of volume_. Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths, unless a coordinate of radiation_wavelength is included to specify the wavelength. Radiative flux is the sum of shortwave and longwave radiative fluxes. "Aerosol" means the system of suspended liquid or solid particles in air (except cloud droplets) and their carrier gas, the air itself. To specify the relative humidity at which the sample was measured, provide a scalar coordinate variable with the standard name of "relative_humidity". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "Standard_temperature_and_pressure" refer to a reference volume at 273.15 K temperature and 1013.25 hPa pressure.