volume_backwards_scattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles

rejected
Created: Nov. 26, 2013
Proposer: Markus Fiebig
Proposed Date: 2013-10-12
13. Mailing list discussion did not reach conclusion.
Change Date: Nov. 26, 2013, 2:50 p.m.
Term: surface_volume_spherical_backscattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol
Unit: m-1
Unit ref: http://vocab.ndg.nerc.ac.uk/term/P061/current/UPRM
AMIP:
GRIB:
The volume spherical backscattering coefficient is the fractional change of radiative flux per unit path length due to redirection of an incident light beam into the rearward hemisphere relative to the incident beam by a component in the reference volume. It is distinct from the backscattering coefficient which isn't integrated over the rearward hemisphere. "Aerosol" means the suspended liquid or solid particles in air (except cloud droplets). "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (RH < 40%) hasn't necessarily been reached. To specify the relative humidity at which the property applies, provide scalar coordinate variable with the standard name of "relative_humidity". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "surface" means that the property applies at the lower boundary of the atmosphere. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa). "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "sizing_relative_humidity". A coordinate variable of radiation_wavelength or radiation_frequency needs to be specified to indicate that the property applies at specific wavelengths or frequencies.
Change Date: Nov. 24, 2014, 4:56 p.m.
Term: [surface_]volume_spherical_backscattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles
Unit: m-1
Unit ref: http://vocab.ndg.nerc.ac.uk/term/P061/current/UPRM
AMIP:
GRIB:
The volume spherical backscattering coefficient is the fractional change of radiative flux per unit path length due to redirection of an incident light beam into the rearward hemisphere relative to the incident beam by a component in the reference volume. It is distinct from the backscattering coefficient which isn't integrated over the rearward hemisphere. "Aerosol" means the suspended liquid or solid particles in air (except cloud droplets). "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (RH < 40%) hasn't necessarily been reached. To specify the relative humidity at which the property applies, provide scalar coordinate variable with the standard name of "relative_humidity". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "surface" means that the property applies at the lower boundary of the atmosphere. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa). "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "sizing_relative_humidity". A coordinate variable of radiation_wavelength or radiation_frequency needs to be specified to indicate that the property applies at specific wavelengths or frequencies.
Change Date: Nov. 24, 2014, 4:58 p.m.
Term: [surface_]volume_backwards_scattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles
Unit: m-1
Unit ref: http://vocab.ndg.nerc.ac.uk/term/P061/current/UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with "specific_" instead of "volume_". Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths unless a coordinate of "radiation_wavelength" or "radiation_frequency" is included to specify the wavelength. "Aerosol" means the suspended liquid or solid particles in air (except cloud droplets). "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (RH < 40%) hasn't necessarily been reached. To specify the relative humidity at which the property applies, provide scalar coordinate variable with the standard name of "relative_humidity". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "surface" means that the property applies at the lower boundary of the atmosphere. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa). "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "sizing_relative_humidity". A coordinate variable of radiation_wavelength or radiation_frequency needs to be specified to indicate that the property applies at specific wavelengths or frequencies.
Change Date: Nov. 24, 2014, 4:59 p.m.
Term: [surface_]volume_backwards_scattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles
Unit: m-1
Unit ref: http://vocab.ndg.nerc.ac.uk/term/P061/current/UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with "specific_" instead of "volume_". Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths unless a coordinate of "radiation_wavelength" or "radiation_frequency" is included to specify the wavelength. "Aerosol" means the system of suspended liquid or solid particles in air (except cloud droplets) and their carrier gas, the air itself. "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (RH < 40%) hasn't necessarily been reached. To specify the relative humidity at which the quantity described by the standard name applies, provide a scalar coordinate variable with the standard name of "relative_humidity". "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "relative_humidity_for_aerosol_particle_size_selection". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa). "surface" means that the property applies at the lower boundary of the atmosphere.
Change Date: Dec. 17, 2014, 5:13 p.m.
Term: volume_backwards_scattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles
Unit: m-1
Unit ref: http://vocab.ndg.nerc.ac.uk/term/P061/current/UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with "specific_" instead of "volume_". Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths unless a coordinate of "radiation_wavelength" or "radiation_frequency" is included to specify the wavelength. "Aerosol" means the system of suspended liquid or solid particles in air (except cloud droplets) and their carrier gas, the air itself. "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (RH < 40%) hasn't necessarily been reached. To specify the relative humidity at which the sample was measured, provide a scalar coordinate variable with the standard name of "relative_humidity". "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "relative_humidity_for_aerosol_particle_size_selection". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa).
Change Date: Jan. 7, 2015, 10:58 a.m.
Term: volume_backwards_scattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles
Unit: m-1
Unit ref: http://vocab.ndg.nerc.ac.uk/term/P061/current/UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with "specific_" instead of "volume_". Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths unless a coordinate of "radiation_wavelength" or "radiation_frequency" is included to specify the wavelength. "Aerosol" means the system of suspended liquid or solid particles in air (except cloud droplets) and their carrier gas, the air itself. "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (relative humidity less than 40 per cent) hasn't necessarily been reached. To specify the relative humidity at which the sample was measured, provide a scalar coordinate variable with the standard name of "relative_humidity". "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "relative_humidity_for_aerosol_particle_size_selection". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa).
Change Date: Aug. 13, 2019, 12:17 p.m.
Term: volume_backwards_scattering_coefficient_at_stp_in_air_due_to_pm2p5_dried_aerosol_particles
Unit: m-1
Unit ref: UPRM
AMIP:
GRIB:
The volume scattering/absorption/attenuation coefficient is the fractional change of radiative flux per unit path length due to the stated process. Coefficients with canonical units of m2 s-1 i.e. multiplied by density have standard names with "specific_" instead of "volume_". Backwards scattering refers to the sum of scattering into all backward angles i.e. scattering_angle exceeds pi/2 radians. A scattering_angle should not be specified with this quantity. The scattering/absorption/attenuation coefficient is assumed to be an integral over all wavelengths unless a coordinate of "radiation_wavelength" or "radiation_frequency" is included to specify the wavelength. "Aerosol" means the system of suspended liquid or solid particles in air (except cloud droplets) and their carrier gas, the air itself. "Dried_aerosol" means that the aerosol sample has been dried from the ambient state, but that the dry state (relative humidity less than 40 per cent) hasn't necessarily been reached. To specify the relative humidity at which the sample was measured, provide a scalar coordinate variable with the standard name of "relative_humidity". "pm2p5" refers to the fraction of aerosol particles with an aerodynamic diameter of less than or equal to 2.5 micrometers, where the size cut is applied under ambient conditions before aerosol humidity, pressure, or temperature are possibly altered. To specify the relative humidity at which the sample was sized, provide scalar coordinate variable with the standard name of "relative_humidity_for_aerosol_particle_size_selection". The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase. "at_stp" refers to a volume at standard conditions of temperature (273.15 K) and pressure (1013.25 hPa).