integral_wrt_depth_of_sea_water_practical_salinity

complete
Created: Oct. 27, 2017
Proposer: Jonathan Gregory / Stephen Griffies / Alison Pamment
Proposed Date: 2017-10-12
CMIP6 - OMIP. Create alias to standardize syntax in all integral names.
Change Date: Oct. 27, 2017, 2:47 p.m.
Term: integral_of_sea_water_practical_salinity_wrt_depth
Unit: m
Unit ref: ULAA
AMIP:
GRIB:
"integral_of_Y_wrt_X" means int Y dX. The data variable should have an axis for X specifying the limits of the integral as bounds. "wrt" means with respect to. Depth is the vertical distance below the surface. Practical Salinity, S_P, is a determination of the salinity of sea water, based on its electrical conductance. The measured conductance, corrected for temperature and pressure, is compared to the conductance of a standard potassium chloride solution, producing a value on the Practical Salinity Scale of 1978 (PSS-78). This name should not be used to describe salinity observations made before 1978, or ones not based on conductance measurements. Conversion of Practical Salinity to other precisely defined salinity measures should use the appropriate formulas specified by TEOS-10. Other standard names for precisely defined salinity quantities are sea_water_absolute_salinity (S_A); sea_water_preformed_salinity (S_*), sea_water_reference_salinity (S_R); sea_water_cox_salinity (S_C), used for salinity observations between 1967 and 1977; and sea_water_knudsen_salinity (S_K), used for salinity observations between 1901 and 1966. Salinity quantities that do not match any of the precise definitions should be given the more general standard name of sea_water_salinity. Reference: www.teos-10.org; Lewis, 1980 doi:10.1109/JOE.1980.1145448.
Change Date: Oct. 27, 2017, 2:48 p.m.
Term: integral_wrt_depth_of_sea_water_practical_salinity
Unit: m
Unit ref: ULAA
AMIP:
GRIB:
"integral_of_Y_wrt_X" means int Y dX. The data variable should have an axis for X specifying the limits of the integral as bounds. "wrt" means with respect to. Depth is the vertical distance below the surface. Practical Salinity, S_P, is a determination of the salinity of sea water, based on its electrical conductance. The measured conductance, corrected for temperature and pressure, is compared to the conductance of a standard potassium chloride solution, producing a value on the Practical Salinity Scale of 1978 (PSS-78). This name should not be used to describe salinity observations made before 1978, or ones not based on conductance measurements. Conversion of Practical Salinity to other precisely defined salinity measures should use the appropriate formulas specified by TEOS-10. Other standard names for precisely defined salinity quantities are sea_water_absolute_salinity (S_A); sea_water_preformed_salinity (S_*), sea_water_reference_salinity (S_R); sea_water_cox_salinity (S_C), used for salinity observations between 1967 and 1977; and sea_water_knudsen_salinity (S_K), used for salinity observations between 1901 and 1966. Salinity quantities that do not match any of the precise definitions should be given the more general standard name of sea_water_salinity. Reference: www.teos-10.org; Lewis, 1980 doi:10.1109/JOE.1980.1145448.
Change Date: Oct. 27, 2017, 2:49 p.m.
Term: integral_wrt_depth_of_sea_water_practical_salinity
Unit: m
Unit ref: ULAA
AMIP:
GRIB:
The phrase "integral_wrt_X_of_Y" means int Y dX. The data variable should have an axis for X specifying the limits of the integral as bounds. "wrt" means with respect to. Depth is the vertical distance below the surface. Practical Salinity, S_P, is a determination of the salinity of sea water, based on its electrical conductance. The measured conductance, corrected for temperature and pressure, is compared to the conductance of a standard potassium chloride solution, producing a value on the Practical Salinity Scale of 1978 (PSS-78). This name should not be used to describe salinity observations made before 1978, or ones not based on conductance measurements. Conversion of Practical Salinity to other precisely defined salinity measures should use the appropriate formulas specified by TEOS-10. Other standard names for precisely defined salinity quantities are sea_water_absolute_salinity (S_A); sea_water_preformed_salinity (S_*), sea_water_reference_salinity (S_R); sea_water_cox_salinity (S_C), used for salinity observations between 1967 and 1977; and sea_water_knudsen_salinity (S_K), used for salinity observations between 1901 and 1966. Salinity quantities that do not match any of the precise definitions should be given the more general standard name of sea_water_salinity. Reference: www.teos-10.org; Lewis, 1980 doi:10.1109/JOE.1980.1145448.