integral_wrt_time_of_air_temperature_deficit

complete
Created: Oct. 26, 2017
Proposer: Jonathan Gregory / Stephen Griffies / Alison Pamment
Proposed Date: 2017-10-12
CMIP6 - OMIP. Create alias to standardize syntax in all integral names.
Change Date: Oct. 26, 2017, 5:35 p.m.
Term: integral_of_air_temperature_deficit_wrt_time
Unit: K s
Unit ref: KSXX
AMIP:
GRIB:
"integral_of_Y_wrt_X" means int Y dX. The data variable should have an axis for X specifying the limits of the integral as bounds. "wrt" means with respect to. Air temperature is the bulk temperature of the air, not the surface (skin) temperature. The air temperature deficit is the air temperature threshold minus the air temperature, where only positive values are included in the integral. Its integral with respect to time is often called after its units of "degree-days". The air_temperature variable, which is the data variable of the integral should have a scalar coordinate variable or a size-one coordinate variable with the standard name of air_temperature_threshold, to indicate the threshold.
Change Date: Oct. 26, 2017, 5:40 p.m.
Term: integral_wrt_time_of_air_temperature_deficit
Unit: K s
Unit ref: KSXX
AMIP:
GRIB:
"integral_of_Y_wrt_X" means int Y dX. The data variable should have an axis for X specifying the limits of the integral as bounds. "wrt" means with respect to. Air temperature is the bulk temperature of the air, not the surface (skin) temperature. The air temperature deficit is the air temperature threshold minus the air temperature, where only positive values are included in the integral. Its integral with respect to time is often called after its units of "degree-days". The air_temperature variable, which is the data variable of the integral should have a scalar coordinate variable or a size-one coordinate variable with the standard name of air_temperature_threshold, to indicate the threshold.
Change Date: Oct. 26, 2017, 5:43 p.m.
Term: integral_wrt_time_of_air_temperature_deficit
Unit: K s
Unit ref: KSXX
AMIP:
GRIB:
The phrase "integral_wrt_X_of_Y" means int Y dX. The data variable should have an axis for X specifying the limits of the integral as bounds. "wrt" means with respect to. Air temperature is the bulk temperature of the air, not the surface (skin) temperature. The air temperature deficit is the air temperature threshold minus the air temperature, where only positive values are included in the integral. Its integral with respect to time is often called after its units of "degree-days". The air_temperature variable, which is the data variable of the integral should have a scalar coordinate variable or a size-one coordinate variable with the standard name of air_temperature_threshold, to indicate the threshold.