sea_water_ph_abiotic_analogue_reported_on_total_scale

complete
Created: Oct. 10, 2016
Proposer: Paul Durack
Proposed Date: 2016-09-28
CMIP6 - OMIP
Change Date: Oct. 10, 2016, 12:32 p.m.
Term: sea_water_ph_reported_on_total_scale_due_to_abiotic_component
Unit: 1
Unit ref: UUUU
AMIP:
GRIB:
Change Date: Oct. 10, 2016, 12:32 p.m.
Term: sea_water_ph_reported_on_total_scale_due_to_abiotic_component
Unit: 1
Unit ref: UUUU
AMIP:
GRIB:
sea_water_pH_reported_on_total_scale is the measure of acidity of sea water, defined as the negative logarithm of the activity of dissolved hydrogen ions plus bisulfate ions in a sea water medium; it can be measured or calculated; when measured the scale is defined according to a series of buffers prepared in artificial seawater containing bisulfate. The quantity may be written as pH(total) = -log([H+](free) + [HSO4-]). The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase.
Change Date: March 22, 2017, 3:54 p.m.
Term: sea_water_ph_abiotic_analogue_reported_on_total_scale
Unit: 1
Unit ref: UUUU
AMIP:
GRIB:
sea_water_pH_reported_on_total_scale is the measure of acidity of sea water, defined as the negative logarithm of the activity of dissolved hydrogen ions plus bisulfate ions in a sea water medium; it can be measured or calculated; when measured the scale is defined according to a series of buffers prepared in artificial seawater containing bisulfate. The quantity may be written as pH(total) = -log([H+](free) + [HSO4-]). The specification of a physical process by the phrase "due_to_" process means that the quantity named is a single term in a sum of terms which together compose the general quantity named by omitting the phrase.
Change Date: March 22, 2017, 3:57 p.m.
Term: sea_water_ph_abiotic_analogue_reported_on_total_scale
Unit: 1
Unit ref: UUUU
AMIP:
GRIB:
sea_water_pH_reported_on_total_scale is the measure of acidity of sea water, defined as the negative logarithm of the activity of dissolved hydrogen ions plus bisulfate ions in a sea water medium; it can be measured or calculated; when measured the scale is defined according to a series of buffers prepared in artificial seawater containing bisulfate. The quantity may be written as pH(total) = -log([H+](free) + [HSO4-]). In ocean biogeochemistry models, an "abiotic analogue" is used to simulate the effect on a modelled variable when biological effects on ocean carbon concentration and alkalinity are ignored.
Change Date: April 20, 2017, 2:59 p.m.
Term: sea_water_ph_abiotic_analogue_reported_on_total_scale
Unit: 1
Unit ref: UUUU
AMIP:
GRIB:
sea_water_pH_reported_on_total_scale is the measure of acidity of sea water, defined as the negative logarithm of the concentration of dissolved hydrogen ions plus bisulfate ions in a sea water medium; it can be measured or calculated; when measured the scale is defined according to a series of buffers prepared in artificial seawater containing bisulfate. The quantity may be written as pH(total) = -log([H+](free) + [HSO4-]). In ocean biogeochemistry models, an "abiotic analogue" is used to simulate the effect on a modelled variable when biological effects on ocean carbon concentration and alkalinity are ignored.